Login

Show/Hide Result of algorithm ICAO_compliance 1.1.4 on FICV-1.0

Checking Failures
TotalCrashFailedTimeoutMemory Limit
4.314%0%4.314%0%0%

Efficiency indicators
Avg Check TimeMax Check Time
1.2 s5.1 s

Memory indicators
Max Check Memory
326.1 MB

Eye Localization Accuracy
Rejecteddeye∈[0;0.1[deye∈[0.1;0.2[deye∈[0.2;0.3[deye≥0.3
1.32%95.46%2.11%0.73%0.38%

Tokenizable
Correct
95.03%

Photographic and Pose-specific Tests
Req.EERFMR100ZeroFMRZeroFNMRRej.Score distributionsFMR(t) and FNMR(t) graphsDET graph
021.7% (1.2% - 2.3%)4.2% 7.3% 3.5% 0.2%
0315.3% (14.2% - 16.3%)98.1% 99.2% 26.4% 15.8%
04-----
052.1% (1.9% - 2.3%)14.6% 20.4% 3.1% 0.2%
062.9% (2.3% - 3.5%)91.5% 100.0% 3.5% 0%
070.2% (0% - 0.4%)0.4% 0.4% 38.5% 0%
080.2% (0% - 0.4%)0% 0.4% 0.4% 0.4%
09-----
100.2% (0% - 0.4%)0% 75.8% 0.4% 1.0%
11-----
129.1% (8.8% - 9.4%)92.7% 99.2% 29.0% 6.9%
131.7% (1.2% - 2.3%)3.1% 18.1% 13.2% 0.6%
141.0% (0.5% - 1.5%)2.5% 100.0% 3.0% 2.0%
15-----
1610.5% (9.2% - 11.8%)97.3% 99.2% 41.7% 1.2%
172.7% (2.3% - 3.1%)100.0% 100.0% 8.6% 20.4%
18-----
191.4% (0.9% - 1.8%)100.0% 100.0% 1.8% 15.8%
206.6% (2.3% - 11.0%)100.0% 100.0% 64.7% 2.3%
216.8% (6.3% - 7.4%)100.0% 100.0% 23.1% 0.8%
22-----
230.6% (0.4% - 0.8%)0% 17.7% 0.8% 0.4%
24-----

Show/Hide Description of algorithm ICAO_compliance 1.1.4

For information or suggestions: fvc@unibo.it Copyright © 2026 Biometric System Laboratory